[email protected]
  1. Home
  2. >>
  3. Q345D Steel
  4. >>
  5. tibial lc dcp locking compression locking plate lcp

tibial lc dcp locking compression locking plate lcp

As the world's leading steel supplier, we can provide a wide range of steel types, including carbon steel, weathering steel, boiler steel, structural steel, etc., and we can meet customers' requirements in any size, as well as the production of steel and complete plant plans. If you are interested in these aspects, please contact us.

If you are interested in our products, please contact us.

    A mechanical comparison of the locking compression plate

    OBJECTIVE:To determine if locking compression plates (LCP) are mechanically advantageous compared to low-contact dynamic compression plates (DCP) when used as a bridging plate in a synthetic model of osteoporotic bone. METHODS:Five synthetic bars (Synbone Osteoporotic bone) were initially tested in compression and the Young's modulus determined. Biomechanical Comparison of Locking Compression Plate To compare the biomechanical properties of locking compression plate (LCP) and a limited contact dynamic compression plate combined with an intramedullary rod (LCDCPR) in a cadaveric, canine, femoral fracturegap model. Study Design. In vitro biomechanical study; nonrandomized, complete block (dog). Sample Population

    Distal Femur Locking Compress Plate Suppliers, all Quality

    Distal Femur Locking Compress Plate, Distal Femur Locking Compress Plate Suppliers Directory - Find variety Distal Femur Locking Compress Plate Suppliers, Manufacturers, Companies from around the World at paper plate machine price ,ceramic plates ,bamboo plates, Implants & Interventional Materials Effectiveness of Locking Versus Dynamic Compression This study compares the results of the locking compression plate (LCP) and the dy-namic compression plate (DCP) in the treatment of diaphyseal forearm fractures in adults and defines the indications for the use of the LCP. Forty-two patients with diaphyseal forearm fractures were retrospectively analyzed. LCP BONE PLATES - Proximal Humerus Locking Plates LCP Combi holes in the plate shaft accept 4.5 mm cortex screws in the dynamic compression unit (DCU) portion, 5.0 mm locking screws in the threaded portion, or a combination of both The preshaped, low-profile plate minimizes potential issues with soft tissues and reduces need for plate contouring

    LCP BONE PLATES - Proximal Humerus Locking Plates

    LCP Combi holes in the plate shaft accept 4.5 mm cortex screws in the dynamic compression unit (DCU) portion, 5.0 mm locking screws in the threaded portion, or a combination of both The preshaped, low-profile plate minimizes potential issues with soft tissues and reduces need for plate contouring LCP Locking Compression PlateLocking Compression Plate (LCP) Implants are intended for mal humerus and distal tibial. LCP 4.5/5.0 Narrow Plates LCP T-Plates 4.5/5.0 LCP 4.5/5.0 Broad Plates plates (standard plates DCP, LC-DCP) have been retained. The same indications apply for LCP plates as for the correspond- Locking Compression Plate with Minimally Invasive Plate Mar 01, 2007 · The LCP plate was removed and replaced with a 4.5 mm LC-DCP plate after decortication and cancellous bone grafting. Two months later the fracture had healed. The second patient, with a history of heavy smoking and chronic alcohol abuse, sustained a Gustillo I° (wound <1 cm) partial articular fracture with split-depression (AO43B2).

    Locking Compression Plates - LCP, DHS & DCS Plates

    The Locking Compression Plates combines locking screw technology with the advanced design of plates to create constructs for use in comminuted fractures or where deficient bone stock or poor bone quality is encountered.By combining locking screw holes with compression slots, the plates can be used as both locking devices and fracture compression devices. Locking plate fixation in distal metaphyseal tibial The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures ( n = 41) to maintain the second column of the ankle so as to achieve indirect reduction Locking plate fixation in distal metaphyseal tibial The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures ( n = 41) to maintain the second column of the ankle so as to achieve indirect reduction

    Metaphyseal locking compression plate as an external

    This involved placement of a nut on the undersurface of the DCP that turned the device into a fixed angle construction. As a modification of this technique, we introduced the standard locking compression plate (LCP, Synthes BV, Zeist, The Netherlands) as an external fixator, and coined the term supercutaneous plating . In this article, we Part of the DePuy Synthes Locking Compression Plate the 3.5 mm LCP Anterolateral Distal Tibia Plate with locking screws. Note:To verify that independent lag screws will not interfere with plate placement, evaluate placement intraoperatively with AP and lateral fluoroscopic images. 3 Insert plate Optional instrument 324.031 Threaded Plate Holder Open the area as necessary to expose the metaphysis. PlatesForm and function - AO Foundationthe Limited Contact Dynamic Compression Plate (LC DCP) (1994) was created. The LC DCP has a fluted undersurface. Footprint of a DCP Footprint of an LC DCP Locking compression plates Since 2001 the Locking Compression Plate (LCP), with combination holes has come into use. The LCP has a combi hole which permits the insertion of

    PlatesForm and function - AO Foundation

    the Limited Contact Dynamic Compression Plate (LC DCP) (1994) was created. The LC DCP has a fluted undersurface. Footprint of a DCP Footprint of an LC DCP Locking compression plates Since 2001 the Locking Compression Plate (LCP), with combination holes has come into use. The LCP has a combi hole which permits the insertion of Large Fragment Locking Compression Plate (LCP®) Locking Compression Plates The Locking Compression Plates (LCP) have these LC-DCP features: 50° of longitudinal screw angulation 14° of transverse screw angulation Uniform hole spacing Load (compression) and neutral screw positions The Locking Compression Plates have combination locking and compression (Combi) holes.